NEW QUESTION 1
What room should have its own dedicated air handling system apart from the computer room?

  • A. Electrical Room
  • B. Break Room
  • C. Printer Room
  • D. Storage Room
  • E. Telecommunications Room

Answer: C

NEW QUESTION 2
why does the entrance room designer need to meet with each anticipated access provider?

  • A. To determine their electrical, space, interface, and other facility requirements
  • B. As an alternative approach to save cost
  • C. To know about hardware requirement only
  • D. none of above

Answer: A

NEW QUESTION 3
What is the flame index spread rating required for all materials hosted in a containment system?

  • A. 10
  • B. 25
  • C. 50

Answer: D

NEW QUESTION 4
What is the most common type of automatic transfer switch?

  • A. Closed transition
  • B. Open transition
  • C. Delayed transition
  • D. Soft load transition

Answer: B

NEW QUESTION 5
What is the recommended headroom for overhead cable tray?

  • A. 3"
  • B. 6"
  • C. 9"
  • D. 12"

Answer: D

NEW QUESTION 6
What is the clearance required between cabinets and the perimeter wall?

  • A. 2 ft
  • B. 4 ft
  • C. 6 ft
  • D. 8 ft

Answer: B

NEW QUESTION 7
What are the minimum separation distances for electrical and telecom services pathways to maintain from their primary and redundant feeds?

  • A. 5 meters (16 feet)
  • B. 10 meters (33 feet)
  • C. 15 meters (49 feet)
  • D. 20 meters (66 feet)

Answer: D

NEW QUESTION 8
what is typical entrance room power requirement?

  • A. 500, to 1500 watts per access provider
  • B. More than 2000 KW
  • C. exactly or less than 300KW
  • D. More than about Million watts

Answer: A

NEW QUESTION 9
where should engineering offices be located?

  • A. adjacent to equipment rooms they support
  • B. in a separate building
  • C. far away from the data center
  • D. inside computer room

Answer: A

NEW QUESTION 10
What is the formula to find the maximum allowable cable depth in a non-solid bottom cable tray?

  • A. H = 50/1 + (L * 0.0007)
  • B. H = 100/1 + (L * 0.0007)
  • C. H = 150/1 + (L * 0.0007)
  • D. H = 200/1 + (L * 0.0007)

Answer: C

NEW QUESTION 11
What 3 standards books should be followed for data center grounding and bonding?

  • A. TIA 942, TIA 607 and IEEE 1100
  • B. UL 467, UL 96A and NFPA 70
  • C. TIA 568, ANSI/TIA-606-B and TIA 568-C.1
  • D. ASHRAE Standard 90.1, ASHRAE Standard 62.1 and ASHRAE Standard 55

Answer: A

NEW QUESTION 12
where is the storage room located?

  • A. away from computer room, adjacent to equipment entrance at data center
  • B. next door to computing area
  • C. outermost point of Data Centre
  • D. Near Backup Generator
  • E. All

Answer: A

NEW QUESTION 13
where should the secured storage area be located?

  • A. adjacent to the non-secured loading dock
  • B. far away as possible from secure data
  • C. adjacent to security offices
  • D. adjacent to the secured loading dock
  • E. None of above

Answer: D

NEW QUESTION 14
What is the minimum raised floor height?

  • A. 6"
  • B. 12"
  • C. 18"
  • D. 24"

Answer: C

NEW QUESTION 15
Where should all Storage and Unpacking activities occur?

  • A. Outside the Building, at a secure location.
  • B. Near the Main Entrance of Data Center
  • C. Inside Computer Room
  • D. Outside Computer room, either in Storage Rooms or Staging Areas located adjacent to Computer Room with Dedicated air Handling
  • E. None of these

Answer: D

NEW QUESTION 16
Where is the recommended location for remote power panels?

  • A. at one or both ends of an equipment row
  • B. outside the building
  • C. inside a sealed room
  • D. suspended from ceiling

Answer: A

NEW QUESTION 17
What is the high temperature that must be maintained in a data center according to TIA- 942?

  • A. 70 degrees
  • B. 75 degrees
  • C. 77 degrees
  • D. 80 degrees
  • E. 85 degrees

Answer: C

NEW QUESTION 18
......