Master the DCDC-002 BICSI Data Center Design Consultant - DCDC content and be ready for exam day success quickly with this Examcollection DCDC-002 braindumps. We guarantee it!We make it a reality and give you real DCDC-002 questions in our BICSI DCDC-002 braindumps.Latest 100% VALID BICSI DCDC-002 Exam Questions Dumps at below page. You can use our BICSI DCDC-002 braindumps and pass your exam.

Free demo questions for BICSI DCDC-002 Exam Dumps Below:

NEW QUESTION 1
What is the first preference regarding utility service, class F4?

  • A. At least two circuits from one substation, same path
  • B. One circuit from one substation, separate paths
  • C. At least two circuits from two separate substations, diverse substation power grids and separate paths
  • D. At least one circuit from two separate substations, different voltage levels

Answer: C

NEW QUESTION 2
What is the recommended front of rack aisle width?

  • A. 2 feet
  • B. 3 feet
  • C. 4 feet
  • D. 5 feet

Answer: C

NEW QUESTION 3
What electrical service feed options are there for a data center?

  • A. Single Entrance/Single Pathway
  • B. Single Entrance/Dual Pathway
  • C. Dual Entrance/Dual Pathway
  • D. All of the above

Answer: D

NEW QUESTION 4
How far should Data Center be located from Commercial Airport?

  • A. At Least 3 Miles
  • B. At Least 5 Miles
  • C. At least 10 miles
  • D. None of the above.

Answer: B

NEW QUESTION 5
What is recommended size ratio of Secure Storage Area?

  • A. 5% of Computer Room Space
  • B. 10% or greater than Available Floor Space
  • C. 15-20% more than Computer Room's Cross Sectional Area
  • D. 10% of Computer Room's Net Square Footage
  • E. None Of These

Answer: D

NEW QUESTION 6
what can take up to40 percent of overall space in the equipment area?

  • A. circulation and support equipment
  • B. principal loads
  • C. computer
  • D. electrical equipments
  • E. redistribution systems
  • F. all of above

Answer: A

NEW QUESTION 7
What is the recommended floor loading capacity for a data center?

  • A. 1000 lbs per s
  • B. ft.
  • C. 1250 lbs per s
  • D. ft.
  • E. 1500 lbs per s
  • F. ft.
  • G. 1750 lbs per s
  • H. ft.
  • I. 2000 lbs per s
  • J. ft.

Answer: C

NEW QUESTION 8
what is the ANSI/TIA-942 typical range of pressure differential regarding positive pressure for data center.

  • A. Less than or equal to –0,1 in water column (-25 Pa)
  • B. More than -0,005 in wc (< -1,24 Pa), but less than or equal to +0,05in wc (+12,4 Pa)
  • C. More than +3in wc (>746Pa),but less than or equaltto+6,in wc(1492 pa))
  • D. Less Than –4,+4 inches water column(-1000 opa ,+100 <pa>)

Answer: A

NEW QUESTION 9
What IBC occupancy category are data centers placed in?

  • A. Category 3
  • B. Category 4
  • C. Category5
  • D. category6

Answer: B

NEW QUESTION 10
What is the ASHRAE TC 9.9 recommended range for humidity levels in a data center?

  • A. 20-50%
  • B. 40-60%
  • C. 60-80%
  • D. 80-100%

Answer: B

NEW QUESTION 11
What type of slope is considered too extreme for a data center site?

  • A. 5%
  • B. 10%
  • C. 15%
  • D. 20%

Answer: C

NEW QUESTION 12
Where should power cable be ran in an access floor?

  • A. Hot aisle
  • B. Cold aisle
  • C. Above the access floor
  • D. Below the access floor

Answer: B

NEW QUESTION 13
What is the low temperature that must be maintained in a data center according to NEB standards?

  • A. 55 degrees
  • B. 60 degrees
  • C. 65 degrees
  • D. 70 degrees
  • E. 75 degrees

Answer: C

NEW QUESTION 14
CORRECT TEXT
What are the equipment clearance/access requirements when designing the door openings and loading dock areas for a data center?


Solution:
Clearance requirements of 10' L x 4' W x 8' H and 7500 pounds

Does this meet the goal?
  • A. Yes
  • B. Not Mastered

Answer: A

NEW QUESTION 15
what are 2 typical printer manufacturer environmental criteria?

  • A. humidity and temperature
  • B. lighting and sound level
  • C. radioactivity measurement and electromagnetic interference
  • D. electrical conductivity and soil contamination

Answer: A

NEW QUESTION 16
What is the appropriate fire rating requirements for a command center?

  • A. 1/2 hour
  • B. 1 hour
  • C. 2 hours
  • D. 3 hours

Answer: B

NEW QUESTION 17
What are the 3 different methods for grounding racks in a computer room?

  • A. Ground bus, direct connections, bond to rack
  • B. Ground conductor, surge protection, equipment rack
  • C. Copper cable, conduit, flexible connector
  • D. AC power, DC power, Ethernet

Answer: A

NEW QUESTION 18
......