The Abreast Of The Times Guide To DES-4122 Test

Master the DES-4122 Specialist - Implementation Engineer PowerEdge Version 2.0 content and be ready for exam day success quickly with this Testking DES-4122 torrent. We guarantee it!We make it a reality and give you real DES-4122 questions in our EMC DES-4122 braindumps.Latest 100% VALID EMC DES-4122 Exam Questions Dumps at below page. You can use our EMC DES-4122 braindumps and pass your exam.

Online EMC DES-4122 free dumps demo Below:

NEW QUESTION 1

An engineer is checking a newly delivered Dell EMC PowerEdge R640 server that will be deployed for a new database environment
The inventory consists of:
DES-4122 dumps exhibit
The server power configuration will be set for gnd redundancy The management switch is 1000 Base-T and the top of rack switches 10Gb
What additional component(s) is needed for this configuration?

  • A. Hot-plug power supply, 750 W - qty 1
  • B. Hot-plug power supply, 1100W - qty 1
  • C. Dell Networking, cable, 40GbE (QSFP+) to 4 x 10GbE SFP+ passive copper breakout cable, 3 meters - qty 2
  • D. C20 to C21, PDU style, 250 V, 16 Amp, 3 5 meters power cord - qty 2

Answer: D

NEW QUESTION 2

What is a characteristic of out-of-band management?

  • A. Dedicated device
  • B. Agent based
  • C. Less secure
  • D. Dependent upon OS

Answer: A

NEW QUESTION 3

What is the purpose of the Silicon-Based Hardware Root of Trust feature in Dell EMC PowerEdge 14G servers?

  • A. Ensures that the installed operating system is authentic
  • B. Ensures that the server has a valid Service Tag number
  • C. Ensures that no unauthorized BIOS or firmware codes are run
  • D. Ensures that the server boots only when connected to a verified network

Answer: C

NEW QUESTION 4

Match each RAID level to its characteristic.
DES-4122 dumps exhibit


Solution:
DES-4122 dumps exhibit

Does this meet the goal?
  • A. Yes
  • B. Not Mastered

Answer: A

NEW QUESTION 5

A technician working with a Dell EMC PowerEdge 14G server observes the PCIe indicator turn solid amber What should they do to take corrective action upon checking the System Event log?
A)
DES-4122 dumps exhibit
B)
DES-4122 dumps exhibit
C)
DES-4122 dumps exhibit
D)
DES-4122 dumps exhibit

  • A. Option A
  • B. Option B
  • C. Option C
  • D. Option D

Answer: C

NEW QUESTION 6

An engineer wants to fully leverage Microsoft Windows Server 2016 for TPM-based guarded host deployment of a 14G server Which BIOS settings need to be used for installing the Windows server?
DES-4122 dumps exhibit

  • A. Option A
  • B. Option B
  • C. Option C
  • D. Option D

Answer: C

NEW QUESTION 7

An engineer needs to upgrade a Dell EMC PowerEdge R440 server from a single PSU to dual PSU configuration. There are unused PSU modules from PowerEdge R430 and R420 servers available, and they have the same wattage ratings.
What should the engineer do to complete the task?

  • A. Add the PowerEdge R420 PSU modules to the PowerEdge R440
  • B. Order a new PSU specific to the existing PowerEdge R440
  • C. Add the PowerEdge R430 PSU modules to the PowerEdge R440
  • D. Configure the PowerEdge R440 PSU with 1+1 configuration

Answer: A

NEW QUESTION 8

How can the ePSA be accessed?

  • A. iDRAC
  • B. Lifecycle Controller
  • C. VMware vSphere plug-in
  • D. OMSA

Answer: A

NEW QUESTION 9

What is the minimum number of components, beside the system board, required to POST?

  • A. PSUs, CPUs, and DIMMs as configured in BIOS
  • B. 1 PSU, 1 DIMM, and 1 CPU only
  • C. 1 PSU and 1 CPU only
  • D. 1 PSU, 1 CPU, 1 DIMM, and PERC SAS controller

Answer: B

NEW QUESTION 10

A technician needs to update the IDRAC license on a Dell EMC PowerEdge R740 server from Express to Enterprise. The server has the following components:
* 2x CPUs
* 384 GB RAM
* 6x 1 TB drives
* 1x PSU
The server is connected to active AC, but it is powered down, and it needs to stay powered down No errors are presently displayed
How can the technician upgrade the license?

  • A. The license cannot be upgraded on a single PSU system
  • B. Power on the server, then connect to the iDRAC and upgrade iDRAC license before powering down the server
  • C. The license cannot be upgraded because the user will not allow the server to be powered on
  • D. Connect to the iDRAC GUI and upgrade the .DRAC license while the server .s powered down

Answer: A

NEW QUESTION 11

What must be done before upgrading OMSA from the 32-bit to the 64-bit version?

  • A. Save the license file
  • B. Disable UAC
  • C. Back up the configuration
  • D. Uninstall the earlier version

Answer: A

NEW QUESTION 12

Which card connects to the PCI bus, is physically smaller than a on the system board of a Dell EMC PowerEdge 14G server?

  • A. NDC
  • B. OCP
  • C. PCIe
  • D. FPGA

Answer: C

NEW QUESTION 13

What is a consideration when populating DIMMs with different types of persistent memory in a Dell EMC PowerEdge 14G server?

  • A. NVDIMMs cannot be mixed with RDlMMs
  • B. NVDIMMs can be mixed only with LRDIMMs
  • C. RDlMMs can be mixed only with NVDIMMs
  • D. LRDIMMs can be mixed only with RDlMMs

Answer: B

NEW QUESTION 14

Refer to the exhibit.
DES-4122 dumps exhibit
Match each callout to the Dell EMC PowerEdge server model shown.
DES-4122 dumps exhibit


Solution:
DES-4122 dumps exhibit

Does this meet the goal?
  • A. Yes
  • B. Not Mastered

Answer: A

NEW QUESTION 15

What is a key feature introduced in OpenManage Mobile v2.0?

  • A. Access servers remotely through OME
  • B. Access SupportAssist reports
  • C. Access a Virtual Console (VNC over SSH) securely
  • D. Access iDRAC remotely

Answer: B

NEW QUESTION 16
......

P.S. Easily pass DES-4122 Exam with 60 Q&As Downloadfreepdf.net Dumps & pdf Version, Welcome to Download the Newest Downloadfreepdf.net DES-4122 Dumps: https://www.downloadfreepdf.net/DES-4122-pdf-download.html (60 New Questions)