Actualtests offers free demo for 350-601 exam. "Implementing and Operating Cisco Data Center Core Technologies", also known as 350-601 exam, is a Cisco Certification. This set of posts, Passing the Cisco 350-601 exam, will help you answer those questions. The 350-601 Questions & Answers covers all the knowledge points of the real exam. 100% real Cisco 350-601 exams and revised by experts!
Check 350-601 free dumps before getting the full version:
NEW QUESTION 1
A network engineer must download a firmware image from a remote location to a Cisco UCS Fabric Interconnect. The software bundle is over 232 MB in size. The file transfer must use encryption and authentication Which protocol must be used to accomplish this goal?
- A. RDP
- B. HTTPS
- C. SCP
- D. TFTP
Answer: C
NEW QUESTION 2
Refer to the exhibit
During a vPC peer switch reload, there is packet loss between the server and the router Which action must be taken to prevent this behavior during future reloads?
- A. Set the routed uplink ports of the Cisco Nexus peers as orphans.
- B. Increase the vPC delay restore timer.
- C. Decrease the OSPF hello and dead interval timers.
- D. Disable vPC ARP synchronize on the vPC peers.
Answer: B
NEW QUESTION 3
Drag and drop the firmware packages from the left onto the software bundles they belong to on the right.
Solution:
Diagram Description automatically generated
Does this meet the goal?
- A. Yes
- B. Not Mastered
Answer: A
NEW QUESTION 4
An engineer must configure a Cisco UCS domain for monitoring and management by the Cisco Intersight SaaS platform. After the setup is complete, administrators must have full control to configure the device through Cisco UCS Manager and Intersight. Which set of actions accomplishes this task?
- A. Configure Devce Connector Access Mode as Allow Control in Device Console Claim the device on Intersight as UCSM Managed Mode.
- B. Configure Device Connector Access Mode as Allow Control in Cisco UCS Manager Claim the device on intersightc as Intersight Managed Mode
- C. Configure Device Connector Access Moao as Allow Control in Device Consol
- D. Claim the device on intersight as Intersight Managed Mode
- E. Configure Device Connector Access Mode as Allow Control in Cisco UCS Manager Claim the device on intersight as UCSM Managed Mode
- F. Option A
- G. Option B
- H. Option C
- I. Option D
Answer: C
NEW QUESTION 5
An engineer must implement a disaster recovery policy for the Cisco UCS infrastructure. The solution must meet these criteria:
The Recovery Point Objective must be 48 hours.
The backup must use encrypted transmission.
The Recovery Time Objective must be 4 hours.
Which configuration set must be used in the scheduled backup to meet these requirements?
- A. Option A
- B. Option B
- C. Option C
- D. Option D
Answer: D
NEW QUESTION 6
An engineer must shut down the Ethernet 1/2 interface when the Ethernet 4/5 interface state is down. Drag and drop the CLI commands from the bottom onto the blanks in the exhibit to implement this EEM. Not all commands are used.
Solution:
Text Description automatically generated
Does this meet the goal?
- A. Yes
- B. Not Mastered
Answer: A
NEW QUESTION 7
Refer to the exhibit.
An engineer configures a new application profile using REST API and receives this error massage. Which method can be used before application profile can be configured?
- A. POST to aaaLogin
- B. POST to aaaRefresh
- C. POST to aaaLogout
- D. GET to aaaListDomains
Answer: A
Explanation:
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/aci/apic/sw/2-x/rest_cfg/2_1_x/ b_Cisco_APIC_REST_API_Configuration_Guide/ b_Cisco_APIC_REST_API_Configuration_Guide_chapter_01.html
NEW QUESTION 8
A network architect considers a Cisco HyperFlex design solution for a company. The proposed solution is for a virtual environment that is not performance-sensitive, but the solution must have high storage capacity and a low cost. Which Cisco HyperFlex storage configuration should be used?
- A. All-Flash
- B. Hybrid
- C. All-SAN
- D. All-NVMe
Answer: B
Explanation:
https://www.cisco.com/c/en/us/products/collateral/hyperconverged-infrastructure/hyperflex-hx-series/white-pap Hybrid contains HDD for capacity.
NEW QUESTION 9
A network engineer must configure a Cisco MDS switch to use the local user database for console access if all AAA servers are unreachable. Which configuration should be applied to complete this task?
- A. aaa authentication login default fallback error local
- B. aaa authentication login console fallback error local
- C. aaa authentication login default local
- D. aaa authentication login console local
Answer: B
NEW QUESTION 10
A Cisco UCS C-Series server is installed at a data center. The server should be managed by the Cisco UCS Manager by using a single cable for management and data traffic. Which configuration should be applied after the Physical connection is established?
- A. UCS-A# scope server 1 UCS-A /server# scope cimcUCS-A /server/cimc # scope mgmt-conn sidebandUCS-A /server/cimc # mgmt-conn-state enabled UCS-A /server/cimc/mgmt-conn* # commit-buffer
- B. UCS-A# scope chassis 1 UCS-A /chassis# scope cimcUCS-A /chassis/cimc # scope mgmt-conn sidebandUCS-A /chassis/cimc/mgmt-conn # mgmt-conn-state enabled UCS-A /chassis/cimc/mgmt-conn* # commit-buffer
- C. UCS-A# scope chassis 1 UCS-A /chassis# scope cimcUCS-A /chassis /cimc # set mgmt-conn-state enabled UCS-A /chassis /cimc/mgmt-conn* # commit-buffer
- D. UCS-A# scope server 1 UCS-A /server# scope cimcUCS-A /server/cimc # scope mgmt-conn sidebandUCS-A /server/cimc/mgmt-conn #set mgmt-conn-state enabled UCS-A /server/cimc/mgmt-conn* # commit-buffer
Answer: D
Explanation:
Example
UCS-A# scope server 1 UCS-A /server # scope cimc
UCS-A /server/cimc # scope mgm
UCS-A /server/cimc # scope mgmt-conn
UCS-A /server/cimc # scope mgmt-conn sideband
UCS-A /server/cimc/mgmt-conn # set mgmt-conn-state enabled UCS-A /server/cimc/mgmt-conn* # commit-buffer
UCS-A /server/cimc/mgmt-conn
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c-series_integration/ucsm3-1/b_C-Series- Integration_UCSM3-1/b_C-Series-Integration_UCSM3-1_chapter_010.html
NEW QUESTION 11
Which behavior defines streaming telemetry as a push model in Cisco devices?
- A. Monitoring clients are pulling data from the network to see real-time statistics
- B. JSON encoded telemetry data is transported using the gRPC protocol
- C. The network devices send data in JSON or GPB format to configured endpoints
- D. Events and network changes generate telemetry data
Answer: D
Explanation:
https://developer.cisco.com/docs/ios-xe/#!streaming-telemetry-quick-start-guide/streaming-telemetry
NEW QUESTION 12
An engineer must optimize ARP responses and reduce unnecessary ARP broadcasts over the VXLAN/EVPN fabric. Which action accomplishes these tasks?
- A. Configure ip proxy-arp under the VLAN SVI associated with the VXLAN VNI.
- B. Configure ip proxy-arp within the VXLAN VNI configuration under the VTEP NVE interface.
- C. Configure suppress-arp within the VXLAN VNI configuration under the VTEP NVE interface.
- D. Configure suppress-arp under the VLAN SVI associated with the VXLAN VNI.
Answer: C
NEW QUESTION 13
Several production and development database servers exist in the same EPG and IP subnet. The IT security policy is to prevent connections between production and development. Which attribute must be used to assign the servers to different microsegments?
- A. Data center
- B. VMM domain
- C. VM name
- D. IP address
Answer: C
Explanation:
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/aci/apic/sw/3-x/virtualization/b_ACI_Virtualization_
NEW QUESTION 14
A new user with access privileges in the Finance department moves to a new Admin department. The user must have access privileges to the Admin department data and applications inside the Cisco UCS Manager Which set of changes must be implemented in Cisco UCS Central for the user to acquire the privileges?
- A. Create an Admin user account and remove the authentication service for the Finance privileges.
- B. Disable the Finance user account and add the authentication service for the Admin privileges.
- C. Create a new locale Admin and add the Admin department to the Admin local
- D. Delete the old locale
- E. Finance and remove the Finance department from the Finance locale.
Answer: C
NEW QUESTION 15
An engineer mus! configure the remote SSH management connectivity for Cisco Nexus 9000 Series Switches to meet these requirements
The connectivity must be permitted from a jump host with an IP address of 10 10.10 10/24
All switches must be permitted to connect via SSH to other devices from the subnet of 10 .20.20.0/24. Which configuration set accomplishes these requirements?
- A. Option A
- B. Option B
- C. Option C
- D. Option D
Answer: B
NEW QUESTION 16
An engineer configures the properties of a cisco UCS cisco integrated Management controller network adapter for a standalone cisco C-Series server. The Fallback Timeout in the vNIC was set to 600. When the failure occurs. The secondary must be used and then fallback when the primary interface becomes available again. Which action be taken to meet these requirements?
- A. Set default VLAN on the adapters.
- B. Increase Cos to 6.
- C. Disable VNTAG mode.
- D. Enable Uplink failover.
Answer: D
Explanation:
Enable Uplink Failover check box - Check this box if traffic on this vNIC should fail over to the secondary interface if there are communication problems. VNTAG mode is required for this option.
Failback timeout field - After a vNIC has started using its secondary interface, this setting controls how long the primary interface must be available before the system resumes using the primary interface for the vNIC. Enter a number of seconds between 0 and 600. VNTAG mode is required for this option.
https://www.cisco.com/en/US/docs/unified_computing/ucs/c/sw/gui/config/guide/1.5/b_Cisco_UCS_C-series_G
NEW QUESTION 17
Refer to the exhibit.
What is the result of implementing this configuration?
- A. The TACACS+ server uses the type-6 encrypted format.
- B. The switch queries the TACACS+ server by using a clear text PAP login.
- C. The timeout value on the TACACS+ server is 10 seconds.
- D. The switch queries the TACACS+ server by using an encrypted text PAP login.
Answer: D
Explanation:
tacacs-server key
To configure a global TACACS+ shared secret key, use the tacacs-server key command. To remove a configured shared secret, use the no form of this command.
tacacs-server key [0 | 7] shared-secret Syntax Description
7 (Optional) Configures a preshared key specified in encrypted text to authenticate communication between the TACACS+ client and server.
NEW QUESTION 18
Refer to the exhibit.
What is the result of executing this python code?
- A. It backs up Cisco switches to Cisco Prime infrastructure.
- B. It sends the switch configuration to Cisco TAC.
- C. It sends a Cisco device backup to a remote destination.
- D. It schedules a backup on a Cisco switch using EEM.
Answer: C
NEW QUESTION 19
What are two types of FC/FCoE oversubscription ratios? (Choose two.)
- A. server storage to end-node count
- B. port bandwidth to uplink bandwidth
- C. edge ISL bandwidth to core ISL bandwidth
- D. host bandwidth to storage bandwidth
- E. switch processing power to end-node processing power
Answer: CD
Explanation:
https://www.ciscolive.com/c/dam/r/ciscolive/us/docs/2017/pdf/BRKDCN-1121.pdf https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/operations/n5k_fcoe_ops.html
NEW QUESTION 20
Refer to the exhibit.
Drag and drop each traffic flow type from the left onto the corresponding number on the right Not all traffic flow types are used
Solution:
Table Description automatically generated
Does this meet the goal?
- A. Yes
- B. Not Mastered
Answer: A
NEW QUESTION 21
......