It is impossible to pass Network-Appliance NS0-520 exam without any help in the short term. Come to Examcollection soon and find the most advanced, correct and guaranteed Network-Appliance NS0-520 practice questions. You will get a surprising result by our Renewal NetApp Certified Implementation Engineer - SAN. ONTAP practice guides.
Check NS0-520 free dumps before getting the full version:
NEW QUESTION 1
You have a 4-node cluster with an AFF A300 HA pair and a FAS8200 HA pair. You plan on using the default storage efficiency settings. With inline data compaction, you estimate that you can save 6% of storage space. AFF A300 volumes that use under 5000 IOPS are moved to a FAS8200 using the volume move command.
In this scenario, what happens to the data after the volume is moved? (Choose two.)
- A. The new written data is not compacted.
- B. The existing data is compacted.
- C. The new written data is compacted.
- D. The existing data is not compacted.
Answer: A
NEW QUESTION 2
Exhibit.
The VMware ESX host discovers only two of four paths to a LUN on a new ONTAP cluster. Referring to the exhibit, which statement Is correct?
- A. The fabric zoning configuration does not allow access to the target LlFs.
- B. The igroup does not contain th
- C. WWPN of one initiator.
- D. The fabric name server is disabled.
- E. The initiator HBA is not connected to the fabric.
Answer: D
NEW QUESTION 3
What is a SAN best practice when initially configuring a Linux FC boot LUN?
- A. Install the Host Utilities in the guest Linux OS.
- B. Map the WWPN of the target.
- C. Disable the HBA port with the host’s BIOS.
- D. Configure multipath to the LUN.
Answer: B
Explanation:
Reference: https://library.netapp.com/ecm/ecm_download_file/ECMP1217221
NEW QUESTION 4
Which statement is correct regarding virtual machine alignment on VMware ESX?
- A. RDM LUNs do NOT suffer from alignment problems because they are accessed directly by VMs.
- B. A VMFS LUN with a LUN type of VMware, will always have properly aligned VMs.
- C. Alignment issues can occur on any protocol including FCP, iSCSI, FCoE, and NFS
- D. msinfo32 or mbrscan can be run for the ESX service console to check for proper alignment of VMs.
Answer: C
NEW QUESTION 5
You are configuring both NVMe and FC on the same AFF A800 2-node ONTAP 9.5 cluster. You are configuring both protocols on the same Cisco FC network switches.
In this scenario, which configuration on the cluster is supported?
- A. a volume with both LUNs and namespaces
- B. an SVM with both nvme and fcp allowed protocols
- C. an AFF A800 node HBA with both NVMe/FC and FC on the same port
- D. a LIF with both fc-nvme and fcp data protocols
Answer: A
NEW QUESTION 6
An administrator who is using the Virtual Storage Console (VSC) creates a new FC datastore on an existing volume. While the datastore was provisioned, two hosts were in maintenance mode. When the maintenance was completed, the two hosts do not have access to the new datastore, but they have access to other datastores on the same volume.
In this scenario, what caused this result?
- A. The VSC cannot create datastores while hosts are in maintenance mode.
- B. During host maintenance, the FC HBAs were replaced with different FC HBAs.
- C. The VSC created a new igroup that contains only the hosts that were online during the datastore creation.
- D. After creation using the VSC, the administrator needs to create a LUN mapping.
Answer: C
NEW QUESTION 7
Exhibit.
The exhibit shows the Inn show command output for the oradata oraFinProd_l LUN. Which two statements ate correct about the LUN'? (Choose two.)
- A. The LUN Is thick provisioned.
- B. The LUN supports SCSI Tin unmap.
- C. The LUN type is Windows.
- D. The LUN is thin provisioned.
Answer: BD
NEW QUESTION 8
After completing the configuration of a new Brocade Fibre Channel switch, which command do you use to verify your configuration?
- A. switchshow
- B. show config
- C. configshow
- D. cfgshow
Answer: C
NEW QUESTION 9
An administrator enabled the FCP protocol on an SVM and created a boot LUN for a Windows Server 2019 server host. The host is attached using multiple paths to the storage SVM. After correctly adding
the LUN to the igroup and setting its LUN ID to 1, the host is unable to boot using the installed FC HBA.
- A. The LUN ID must be set to 0
- B. The LUN ID must be set to 255
- C. During the boot process, using FCP is not supported by Netapp
- D. During the boot process, using FCP is not supported by Microsoft
Answer: A
Explanation:
Create the LUN that you want to use as a boot device, and map it to the igroup as LUN ID 0 You can find more information on this link:
https://library.netapp.com/ecmdocs/ECMP1656701/html/GUID-76BFD6AC-BC2A-419A-9DD3-D98423B2B6
NEW QUESTION 10
Referring to the exhibit, which two elements are required for NVMe host access with ONTAP 9.5 and using supported AFF nodes? (Choose two.)
- A. You need 16 Gb FC HBAs installed in the AFF nodes.
- B. You must have the license installed for NVMe support in the cluster.
- C. You must have the license installed for FC support in the cluster.
- D. You need 32 Gb FC HBAs installed in the AFF nodes.
Answer: CD
NEW QUESTION 11
Referring to the exhibit, which WWPN would safely be removed from the zone?
- A. 50:0a:09:84:8d:7c:51:d5
- B. 20:09:00:a0:98:32:99:07
- C. 21:00:00:c0:dd:19:4b:f3
- D. 20:27:00:a0:98:32:99:07
Answer: C
Explanation:
Important:
A WWN pool can include only WWNNs or WWPNs in the ranges from 20:00:00:00:00:00:00:00 to 20:FF:FF:FF:FF:FF:FF:FF or from 50:00:00:00:00:00:00:00 to 5F:FF:FF:FF:FF:FF:FF:FF. All other WWN
ranges are reserved. To ensure the uniqueness of the Cisco UCS WWNNs and WWPNs in the SAN fabric, we recommend that you use the following WWN prefix for all blocks in a pool:
20:00:00:25:B5:XX:XX:XX
You can find more information on this link: https://www.cisco.com/en/US/docs/unified_computing/ucs/sw/cli/config/guide/1.4.1/CLI_Config_Guide_1_4_1
NEW QUESTION 12
Exhibit.
You are adding a boot LUN for a new server. The server uses FCP attached through a CNA. The ONTAP cluster is also attached to the same fabric by way of UTA2. You configure the zoning for the fabric as shown in the exhibit. You discover that the server cannot see its boot LUN.
What is the problem with your zoning configuration?
- A. The zone set must have the same name as the zone.
- B. The zone was not activated.
- C. The zone used a wrong zone ID.
- D. The WWPN for the NetApp LIF is incorrect.
Answer: D
NEW QUESTION 13
Referring to the exhibit, which two actions would you perform to ensure that each host has valid multipathing? (choose two)
- A. Verify that the VLANs are properly configured on the switches
- B. Verify that the VLANs are properly configured on the ONTAP cluster
- C. Verify that ALUA is enabled on the switches
- D. Verify that ISCSI service is started on the ONTAP cluster
Answer: AB
Explanation:
Iscsi is already started, we can not run those commands successfully if the protocol is not started ALUA is enabled on hosts, It is not enabled on switches
VLANs are configured on the Netapp and switches, they need to be properly configured on both sides to work correctly
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-nmg%2FGUID-52AE6E9C-13B6
NEW QUESTION 14
Your customer asks you to configure a newly installed FAS8300 for an FC host connection. Referring to the exhibit, which step accomplishes this task?
- A. Configure the ports 0e and 0f as a mode of CNA
- B. Configure the ports 0e and 0f as type of target
- C. Configure the ports 0e and 0f as status admin up
- D. Configure the ports 0e and 0f as status admin down
Answer: B
Explanation:
To change the port type from initiator to target you need to take the port offline The ports need to be on target mode to present LUNs to the hosts.
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanag%2FGUID-193C6818-EDB
NEW QUESTION 15

Referring to the exhibit, what is the problem with switch port 0?
- A. The transmit and receive links were switched.
- B. The SFP+ is faulty.
- C. The receive power is lower.
- D. The link is not connected.
Answer: C
NEW QUESTION 16
A company wants to use jumbo frames to improve performance with their iSCSI network. When setting up the Ethernet switches for jumbo frames, which three components need to be configured? (Choose three.)
- A. Ethernet port on Management Console
- B. Ethernet port on RLM
- C. Ethernet port on host system
- D. Ethernet port on storage device
- E. Ethernet port on FC switch
- F. Ethernet switch ports being used
Answer: CDF
NEW QUESTION 17
Which resource would you use to verify whether a specific SAN configuration is supported by NetApp?
- A. SAN Configuration Guide
- B. Hardware Universe (HWU)
- C. Active IQ
- D. Interoperability Matrix Tool (IMT)
Answer: A
Explanation:
Reference: https://docs.netapp.com/ontap-9/topic/com.netapp.doc.dot-cm-sanconf/SAN%20configuration.pdf
NEW QUESTION 18
Click the Exhibit button.
You notice that your volume named vol1 has a temporary volume that is doubling the space that is used by the volume.
In this scenario, which operation caused the volume to take up twice the space?
- A. FlexClone
- B. SnapRestore
- C. FlexGroup
- D. SnapMirror
Answer: D
Explanation:
Reference:
https://community.netapp.com/t5/Data-ONTAP-Discussions/Volume-takes-much-more-space-than- expected/td-p/100619
NEW QUESTION 19
......
P.S. Easily pass NS0-520 Exam with 234 Q&As Dumps-files.com Dumps & pdf Version, Welcome to Download the Newest Dumps-files.com NS0-520 Dumps: https://www.dumps-files.com/files/NS0-520/ (234 New Questions)