Your success in Cisco 642-980 is our sole target and we develop all our 642-980 braindumps in a way that facilitates the attainment of this target. Not only is our 642-980 study material the best you can find, it is also the most detailed and the most updated. 642-980 Practice Exams for Cisco CCNP Data Center 642-980 are written to the highest standards of technical accuracy.


♥♥ 2021 NEW RECOMMEND ♥♥

Free VCE & PDF File for Cisco 642-980 Real Exam (Full Version!)

★ Pass on Your First TRY ★ 100% Money Back Guarantee ★ Realistic Practice Exam Questions

Free Instant Download NEW 642-980 Exam Dumps (PDF & VCE):
Available on: http://www.surepassexam.com/642-980-exam-dumps.html

Q41. In a Cisco Data center network, what troubleshooting step would you do first when having a npv issue? 

A. Check to see if npv is enable 

B. Check name server database to see if it recognizes device 

C. Check detail config of FCNS database 

D. Check the show-tech-support detail 

Answer: A 


Q42. Refer to the exhibit. 

A zone merge failure occurs with the above error log. What is the problem? 

A. Two switches have the same zone set name but different zone members. 

B. Two switches have different zone names and different members. 

C. Two switches have the same zone set name and the same members. 

D. Two switches have different zone names. 

Answer: A 


Q43. Which statement is true regarding the port channel 100 and 101 configurations between the Nexus 7010 switches? 

A. The vPC assignments on N7010-C2 are incorrectly swapped 

B. N7010-C1 is not allowing any active VLAN traffic to pass on Po100 and Po101. 

C. LACP is not configured to initiate negotiations. 

D. The vPC peer-keepalive is down between the two Nexus 7000 switches. 

Answer: A 

Explanation:

The vPC assignments on N7010-C2 are incorrectly swapped.

The “show vpc” command will show you that the keepalives are active, and that there areactive VLANs. The “show port-channel summary” command shows that LACP is enabled.


Q44. Which statement would explain why the overlay interface on an OTV edge device is not in the up state? 

A. The site identifiers are identical within a multihomed site. 

B. Multicast groups are not mapped to a range of SSM addresses to carry the multicast traffic. 

C. An adjacency server is not configured for connectivity over a multicast transport. 

D. The OTV IS-IS metrics do not match across all adjacent OTV edge devices. 

Answer: B 


Q45. Refer to the exhibit. 

A customer is having difficulty getting NPV working. What is the cause of the problem? 

A. The core NPV device is not enabled. 

B. The core NPV device is not a switch. 

C. The core NPV device is not configured on both ends. 

D. The core NPV device is not configured on the upstream port. 

Answer: B 


Q46. Refer to the exhibit. 

The customer informs you of a problem they are encountering. What is the cause of the problem? 

A. The core upstream switch does not have NPIV enabled. 

B. The downstream switch does not have NPIV enabled. 

C. NPIV has been disabled on all switches. 

D. NPIV has been configured but not enabled on the uplink port. 

Answer: A